Backup Power Kit Guide: Simple Solar Kits for 1, 2 & 4 Weeks

POWER FIT SHOP Β· LEARN & GUIDES
A backup power kit is a portable power station (a big rechargeable battery) plus solar panels that refill it. You don't need to power your whole house. Most families just want to keep the few things that matter most running: phones and lights, a CPAP, the refrigerator.
This guide sizes a kit in three steps, rates each example kit for bad weather, and compares kits from Anker SOLIX, EcoFlow, Jackery and BLUETTI, from about $419. Every number shows its math. The main guide comes first; the detailed tables and methods are in the Deep Dive at the bottom.
Last updated: November 21, 2026. Specs from each manufacturer's official pages and manuals; prices and stock from our store on that date. Numbers are planning estimates from specs and math, not our own lab tests.
New to solar generators? Start with our How to Choose a Solar Generator guide. Have a well pump? See our Refrigerator and Well Pump Solar Sizing Guide.
Table of Contents
- Find Your Kit in 3 Questions
- The Rule-of-Thumb Card
- Step 1: What Do You Need to Power?
- Will It Start? Output and Surge Watts
- Step 2: How Long, and How Sure?
- How We Rate Weather Resilience
- Step 3: Example Kits
- Compare Every Kit
- When a Generator Helps (and Safety)
- CPAP and Medical Devices
- Well Pumps and 240V
- Real-Life Examples
- Planning Checklist
- FAQ
- Deep Dive: watts table, measuring your fridge, worksheet, sun hours, cloudy days, big panel arrays, pass-through charging, panel and battery tips, upgrades, how we calculated, mistakes, glossary
Find Your Kit in 3 Questions
| Tier | With a generator (lowest cost) | No generator (weather rating) |
|---|---|---|
|
1. Phones & lights about 200Wh a day |
Jackery 300 v2 kit $419 + β½ 50β75 min a day |
Jackery 1000 v2 kit $686 Β· β Strong for 1, 2 and 4 weeks |
|
2. + CPAP & fan about 760Wh a day |
EcoFlow DELTA 3 Classic kit $796 + β½ 35β55 min a day |
1 week: EcoFlow DELTA 3 Max kit $1,450 β
Strong 2 or 4 weeks: BLUETTI AC200PL kit $1,913 β Strong |
|
3. + Refrigerator about 1,350Wh a day |
EcoFlow DELTA 3 Max kit $1,450 + β½ 45β70 min a day |
EcoFlow TITAN 5000 Classic + 10 panels $4,257.37 Β· β Strong for 1, 2 and 4 weeks |
|
4. Big backup about 2,110Wh a day |
Ask us: a generator can shrink these kits | 1 week: TITAN 5000 Classic + 10 panels $4,257.37 π‘ Good, or Anker 2 Γ F3800 Plus + 2 panels $7,297 β
Strong 2 or 4 weeks: TITAN + 14 panels $4,813.37 π‘ Good, or Anker + 4 panels $8,329 β Strong |
Ratings are explained in How we rate weather resilience. Planning estimates, not guarantees. Store prices, checked Nov 21, 2026.
The Rule-of-Thumb Card
- Add it up: watts Γ hours for each device = Wh a day.
- Battery for 2 days with no sun: battery Wh β₯ your Wh a day Γ 2.5. (That is 2 days Γ· 0.8 for losses.)
- Panels to break even in weak sun (3 h): panel watts β your Wh a day Γ· 1.8.
- Output: rated watts β₯ everything on at once; surge β₯ the biggest motor start.
- Plan B: a generator, more panels or a turn-off list for storm weeks.
Example, Tier 2 (760Wh a day): battery about 1,900Wh or more, panels about 420W to break even.
Step 1: What Do You Need to Power?
Pick the card that matches what you need. Watts (W) are how hard a device works right now; watt-hours (Wh) are energy over time. A 10W lamp on for 5 hours uses 10 Γ 5 = 50Wh. Add up a day and you have your Wh per day.

| Tier | What it powers | How we figured it | Wh per day |
|---|---|---|---|
| 1 | Phones or a tablet Two LED lamps A radio or Wi-Fi router |
Daily charging: 50Wh 10W each Γ 5 hours: 100Wh 10W Γ 5 hours: 50Wh |
200 |
| 2 | Everything in Tier 1 A CPAP (no heated humidifier or hose) A small fan |
200Wh 40W Γ 8 hours: 320Wh 30W Γ 8 hours: 240Wh |
760 |
| 3 | A full-size refrigerator Phones Two LED lamps |
Planning allowance: 1,200Wh 50Wh 100Wh |
1,350 |
| 4 | A full-size refrigerator Wi-Fi router and modem Five LED lights Phones and a laptop |
1,200Wh 15W Γ 24 hours: 360Wh 50W total Γ 5 hours: 250Wh Daily charging: 300Wh |
2,110 |
Your numbers will differ. Measure your fridge, check the typical watts table, or fill in the worksheet in the Deep Dive.
Will It Start? Output and Surge Watts
- Energy (Wh): do the battery and solar cover your Wh a day? That is what the tiers measure.
- Output (W): can it run everything that is on at the same time? Stay under the rated output.
- Surge (W): can it start the motors? Fridges, freezers, pumps and air conditioners can draw 2β5 times their running watts for a moment (our How to Choose guide). Our example there uses about 1,200W for a fridge starting; yours may differ, so check your fridge's maker or ask us.
The two main Tier 3 fridge kits, the EcoFlow DELTA 3 Max and BLUETTI AC200PL, have 2,400W output with 4,800W and 3,600W surge. The Jackery HomePower 1000 Plus v2 + pack example has 1,800W output (3,600W peak). The BLUETTI AC180P lists 2,700W "Power Lifting" for heating devices, not a motor-starting surge, so we don't count on it for motors. The smallest kit, the Jackery 300 v2, is 300W (600W surge): fine for phones, lamps and a router, but not a fridge, microwave or anything that heats.
Microwaves: the big number on the front is cooking power. The label on the back lists the input, which is higher (for example, 1,500W input for a 1,000W Sharp). Use the input number.
Step 2: How Long, and How Sure?
Pick the longest outage you want to be ready for. "4 weeks" doesn't mean the battery holds 4 weeks of power: the panels refill most or all of each day's use, so the kit keeps going.
A 100W panel in weak sun: 100 Γ 0.75 Γ 3 = 225Wh a day.
- Panels rarely make their full rated watts (heat, angle, dust and charging losses), so we count 75%.
- We plan with weak sun: 3 peak sun hours a day. That is below the normal monthly averages for Florida, Puerto Rico and Hawaii in our sun-hours table, but it is not a worst-case storm number. Northern winters and the days right after a storm can be much lower.
How We Rate Weather Resilience
Lasts the whole period in weak sun with at least 25% to spare, and a full battery covers at least 2 days with no sun at all. Tier 3β4 kits must also pass with an extra 15W of idle draw all day.
Lasts the period in weak sun with at least 10% to spare, but misses a Strong test (often the 2-day reserve). Keep a backup: a generator, more panels, or a turn-off list.
Falls short in weak sun. We show about how many minutes of generator a day it needs.
Step 3: Example Kits
Example kits for each tier, built from products we carry today, each rated for 1, 2 and 4 weeks in weak sun.
Tier 1: Phones & lights

1,500W output, 3,000W surge Β· 23.8 lb
300W output, 600W surge Β· 8.2 lb
Other kits that fit this tier:
- EcoFlow DELTA 3 Classic + 160W panel ($796): Strong for 1, 2 and 4 weeks
- BLUETTI AC180P + 200W panel ($1,145): Strong for 1, 2 and 4 weeks
- Anker SOLIX C1000 Gen 2 (no panel) ($608): Needs backup: add about 15β25 min of generator a day
Tier 2: + CPAP & fan

2,400W output, 4,800W surge Β· 44.8 lb
1,800W output, 3,600W surge Β· 26.6 lb
Other kits that fit this tier:
- BLUETTI AC200PL + 2 panels ($1,913): Strong for 1, 2 and 4 weeks
- BLUETTI AC180P + 350W panel ($1,467): Good for 1 week. For 2 and 4 weeks, add about 15β25 min of generator a day
- Jackery HomePower 1000 Plus v2 + 2 panels ($926): Needs backup: add about 40β60 min of generator a day
- Jackery Explorer 1500 v2 + 2 panels ($1,439): Needs backup: add about 30β45 min of generator a day
Tier 3: + Refrigerator

2,400W output, 4,800W surge Β· 44.8 lb
2,400W output, 3,600W surge Β· 62.4 lb
Other kits that fit this tier:
- Jackery HomePower 1000 Plus v2 + 1 pack + 2 panels ($2,097): Needs backup: add a daily generator top-up (ask us how long)
Want a fridge with no generator? That takes a bigger battery and more panels. See the Tier 4 big-backup examples.
Tier 4: Big backup: fridge, Wi-Fi, lights and more

Each kit is a main unit plus extra batteries and panels, rated for the period shown. The big panel arrays take real space and setup: see big panel arrays.
TITAN 5000 Classic + 10 panels
See main unit
TITAN 5000 Classic + 14 panels
See main unit
Warranty note: The Y-branch pair in the TITAN 5000 Classic kits is a Victron Energy MC4-Y splitter pair, not an EcoFlow part. EcoFlowβs TITAN 5000 manual says Y-branch cables can be used for a parallel setup, but EcoFlowβs US warranty says it does not cover non-EcoFlow hardware, or use of EcoFlow equipment with third-party accessories. If you want an all-EcoFlow setup for warranty peace of mind, ask us before you buy.
2 Γ F3800 Plus + 2 panels
See main unit
2 Γ F3800 Plus + 4 panels
See main unit
HomePower 1000 Plus v2 + 5 packs + 4 panels
See main unit
Lasts about 6 days in weak sun (about 10 in good sun) in our model, so it needs backup for a full week. For longer, call us.
Anker: each F3800 Plus is 6,000W on its own outlets. Anker rates two units at 12,000W combined only when both connect through the Smart Home Power Kit (Home Power Panel), which is included in this kit and is installed by a licensed electrician.
Puerto Rico customers:
Apex 300 + 2 Γ B500K + 2 panels
See main unit
Apex 300 + 3 Γ B500K + 2 panels
See main unit
Apex 300 + 6 Γ B500K + 2 panels
See main unit
These parts are stocked for pickup in Puerto Rico. Elsewhere, ask us for the closest BLUETTI match.
Want one of these put together for you? Call or text us and we'll build the full kit.
Compare Every Kit
All example kits in one table. "No sun at all" is how long a full battery lasts for that tier with zero solar. "Sun hours to break even" is how much sun a day the panels need to cover the whole day's use.
| Kit | Price | Battery + solar | AC output (surge) | Weight (heaviest pieces) | No sun at all | Sun hours to break even | Weather rating, weak sun |
|---|---|---|---|---|---|---|---|
| Tier 1 Jackery Explorer 300 v2 + 40W panel | $419 | 288Wh + 40W solar | 300W (600W) | 8.2 lb | about 1 day | 8.3 h | 1 wk Needs backup Β· 2 wk Needs backup Β· 4 wk Needs backup |
| Tier 1 Anker SOLIX C1000 Gen 2 (no panel) | $608 | 1,024Wh + no panel | 2,000W (3,000W) | 24.9 lb | 4+ days | no panel | 1 wk Needs backup Β· 2 wk Needs backup Β· 4 wk Needs backup |
| Tier 1 Jackery Explorer 1000 v2 + 100W panel | $686 | 1,070Wh + 100W solar | 1,500W (3,000W) | 23.8 lb | 4+ days | 3.3 h | 1 wk Strong Β· 2 wk Strong Β· 4 wk Strong |
| Tier 1 EcoFlow DELTA 3 Classic + 160W panel | $796 | 1,024Wh + 160W solar | 1,800W (3,600W) | 26.6 lb | 4+ days | 2.1 h | 1 wk Strong Β· 2 wk Strong Β· 4 wk Strong |
| Tier 1 BLUETTI AC180P + 200W panel | $1,145 | 1,440Wh + 200W solar | 1,800W (not publishedβ ) | 35.3 lb | 5+ days | 1.7 h | 1 wk Strong Β· 2 wk Strong Β· 4 wk Strong |
| Tier 2 EcoFlow DELTA 3 Classic + 160W panel | $796 | 1,024Wh + 160W solar | 1,800W (3,600W) | 26.6 lb | about 1 day | 7.9 h | 1 wk Needs backup Β· 2 wk Needs backup Β· 4 wk Needs backup |
| Tier 2 Jackery HomePower 1000 Plus v2 + 2 panels | $926 | 1,024Wh + 200W solar | 1,800W (3,600W) | 23.8 lb | about 1 day | 6.3 h | 1 wk Needs backup Β· 2 wk Needs backup Β· 4 wk Needs backup |
| Tier 2 Jackery Explorer 1500 v2 + 2 panels | $1,439 | 1,536Wh + 200W solar | 2,000W (4,000W) | 32 lb | about 1Β½ days | 6.3 h | 1 wk Needs backup Β· 2 wk Needs backup Β· 4 wk Needs backup |
| Tier 2 EcoFlow DELTA 3 Max + 2 panels | $1,450 | 2,048Wh + 320W solar | 2,400W (4,800W) | 44.8 lb | about 2 days | 4.0 h | 1 wk Strong Β· 2 wk Needs backup Β· 4 wk Needs backup |
| Tier 2 BLUETTI AC180P + 350W panel | $1,467 | 1,440Wh + 350W solar | 1,800W (not publishedβ ) | 35.3 lb | about 1Β½ days | 3.6 h | 1 wk Good Β· 2 wk Needs backup Β· 4 wk Needs backup |
| Tier 2 BLUETTI AC200PL + 2 panels | $1,913 | 2,304Wh + 400W solar | 2,400W (3,600W) | 62.4 lb | about 2Β½ days | 3.2 h | 1 wk Strong Β· 2 wk Strong Β· 4 wk Strong |
| Tier 3 EcoFlow DELTA 3 Max + 2 panels | $1,450 | 2,048Wh + 320W solar | 2,400W (4,800W) | 44.8 lb | about 1 day | 7.0 h | 1 wk Needs backup Β· 2 wk Needs backup Β· 4 wk Needs backup |
| Tier 3 BLUETTI AC200PL + 2 panels | $1,913 | 2,304Wh + 400W solar | 2,400W (3,600W) | 62.4 lb | about 1Β½ days | 5.6 h | 1 wk Needs backup Β· 2 wk Needs backup Β· 4 wk Needs backup |
| Tier 3 Jackery HomePower 1000 Plus v2 + 1 pack + 2 panels | $2,097 | 3,072Wh + 200W solar | 1,800W (3,600W) | 23.8 lb + 32.6 lb pack | about 2 days | 11.2 h | 1 wk Needs backup Β· 2 wk Needs backup Β· 4 wk Needs backup |
| Tier 4 EcoFlow TITAN 5000 Classic + 10 panels | $4,257.37 | 5,018Wh + 1,000W solar | 4,000W, 120V only (surge not published) | 102.5 lb | about 2 days | 3.5 h | 1 wk Good Β· 2 wk Needs backup Β· 4 wk Needs backup |
| Tier 4 EcoFlow TITAN 5000 Classic + 14 panels | $4,813.37 | 5,018Wh + 1,400W solar | 4,000W, 120V only (surge not published) | 102.5 lb | about 2 days | 2.5 h | 1 wk Good Β· 2 wk Good Β· 4 wk Good |
| Tier 4 Anker SOLIX 2 Γ F3800 Plus + 2 panels | $7,297 | 7,680Wh + 880W solar | 6,000W per unit, 120/240V; 12,000W only through the included Smart Home Power Kit* | 136.7 lb each | about 3 days | 4.0 h | 1 wk Strong Β· 2 wk Needs backup Β· 4 wk Needs backup |
| Tier 4 Anker SOLIX 2 Γ F3800 Plus + 4 panels | $8,329 | 7,680Wh + 1,760W solar | 6,000W per unit, 120/240V; 12,000W only through the included Smart Home Power Kit* | 136.7 lb each | about 3 days | 2.0 h | 1 wk Strong Β· 2 wk Strong Β· 4 wk Strong |
| Tier 4 Jackery HomePower 1000 Plus v2 + 5 packs + 4 panels | $6,831 | 11,264Wh + 400W solar | 1,800W (3,600W peak) | 23.8 lb + 32.6 lb per pack | 4+ days | 8.8 h | 1 wk Needs backup Β· 2 wk Needs backup Β· 4 wk Needs backup |
| Tier 4 BLUETTI Apex 300 + 2 Γ B500K + 2 panels (Puerto Rico pickup) | $6,766 | 13,005Wh + 700W solar | 3,840W, 120/240V | 83.8 lb + 99.2 lb per B500K | 4+ days | 5.0 h | 1 wk Strong Β· 2 wk Needs backup Β· 4 wk Needs backup |
| Tier 4 BLUETTI Apex 300 + 3 Γ B500K + 2 panels (Puerto Rico pickup) | $8,622 | 18,125Wh + 700W solar | 3,840W, 120/240V | 83.8 lb + 99.2 lb per B500K | 6+ days | 5.0 h | 1 wk Strong Β· 2 wk Good Β· 4 wk Needs backup |
| Tier 4 BLUETTI Apex 300 + 6 Γ B500K + 2 panels (Puerto Rico pickup) | $14,190 | 33,485Wh + 700W solar | 3,840W, 120/240V | 83.8 lb + 99.2 lb per B500K | 12+ days | 5.0 h | 1 wk Strong Β· 2 wk Strong Β· 4 wk Good |
Output, surge and weight from each maker's spec pages and manuals. *Anker's 12,000W needs both units on the included Smart Home Power Kit, installed by an electrician. β BLUETTI lists 2,700W for the AC180P as Power Lifting (heating devices only). The EcoFlow TITAN 5000 Classic has no published surge figure. Over about 50 lb, plan on two people or a hand truck. Prices are store prices on Nov 21, 2026.
When a Generator Helps
A small gas generator is the simplest backup to solar. You don't run it all day: plug the power station's charging cable into it for a short time each day.
- How long: in our example kits, about 5 to 75 minutes a day in weak sun, from each maker's published AC charging time. The higher number allows for slower charging near full, heat, a lower charge setting, or powering devices while charging.
- What size: the generator's running watts must cover the AC charging watts plus anything you power while charging. The Cummins Onan P2500i ($1,068, 2,200W running, 2,500W starting) fits the Tier 1 to 3 examples when you keep that total under 2,200W, which may mean turning down the charge rate in the app. Charge the BLUETTI AC200PL in Standard mode (1,200W max, per its manual), not Turbo (2,400W).
- Charging and powering at once (pass-through): most power stations can do both, but limits differ. See pass-through charging.

- Run a gas generator outdoors only. Never in a home, garage, basement, crawl space or shed, even with doors or windows open. A balcony or patio next to your home is not safe.
- Keep it at least 20 feet from your home, with the exhaust pointed away from doors, windows and vents (U.S. CPSC and CDC guidance).
- Install battery-powered CO alarms inside your home. A generator with automatic CO shutoff adds protection.
- Keep it dry, use outdoor-rated cords sized for the load, let it cool before refueling, and store fuel away from the house.
- Feeling dizzy, sick or weak near a generator? Get to fresh air right away and call 911.
CPAP and Medical Devices
- Ask about a DC power cord. Many CPAP makers sell a DC cord or converter for battery use, which skips the AC inverter and its losses. ResMed, for example, recommends a DC-to-DC converter over an inverter when running its machines from a battery, and notes its humidifier uses considerably more power. Use only the one your supplier approves.
- The humidifier and heated hose use the most power. Ask your doctor whether it's OK to turn them down or off during an outage.
- Automatic switchover: several example units list a UPS switchover under 10 milliseconds, including the EcoFlow DELTA 3 Classic and DELTA 3 Max and the Jackery HomePower 1000 Plus v2. That is a maker spec, not a medical certification. Ask your supplier whether your machine can run that way.
- Oxygen concentrators and other equipment can use much more power than a CPAP. Check the label and plan with your supplier.
Well Pumps and 240V: Which Way to Go?
- Check the pump's volts. Many well pumps run on 240V, often on a two-pole breaker. Your well installer can confirm.
- 120V pump: it may run on a large 120V unit with enough surge. Pumps can pull 2β3 times their running watts when they start (our Fridge & Well Pump guide).
- 240V pump: you need 240V output. The Anker SOLIX F3800 Plus and BLUETTI Apex 300 units in Tier 4 have it, but our Tier 4 numbers don't include a pump, so the kit must be sized for it. Connecting to the pump circuit needs a transfer switch or home panel installed by a licensed electrician.
- Size it: our Refrigerator and Well Pump Solar Sizing Guide plans about 1,000Wh for each hour a Β½ HP pump runs. Then call us and we'll match a kit.
Real-Life Examples
Hurricane week in Florida
Need: fridge, phones and lights for a week (Tier 3, about 1,350Wh a day), with little sun right after the storm.
With a generator: the EcoFlow DELTA 3 Max kit ($1,450) runs about 2 days in weak sun, then needs about 45β70 minutes of generator a day.
No generator: the EcoFlow TITAN 5000 Classic + 10 panels ($4,257.37) rates β Strong for Tier 3: about 3 days with no sun, and it keeps going in weak sun.
An apartment with a CPAP
Need: CPAP, small fan, phones and lamps (Tier 2, about 760Wh a day). No generator: it can't be used safely on a balcony or indoors.
Pick: the EcoFlow DELTA 3 Max kit ($1,450), β Strong for 1 week, or the BLUETTI AC200PL kit ($1,913), β Strong for 1 to 4 weeks. A shaded balcony makes less: see cloudy days.
A rural home with a well
Need: fridge, lights, Wi-Fi, plus water. The pump is the hard part: often 240V, with a big startup surge.
Path: confirm the pump's volts and size with your well installer, see our Fridge & Well Pump guide, then a 120/240V system installed with an electrician. Call us and we'll size it with you.
Your Planning Checklist
- Make your device list and add up your Wh a day (or measure it).
- Choose a kit rated β Strong for your period, or a π‘ Good or β½ kit plus a generator plan.
- Charge to full and keep it topped up in storm season. Do a test day and learn the screen.
- Pick a sunny, safe spot for the panels and a cool, dry indoor spot for the power station.
- Keep cables, chargers, a flashlight and battery-powered CO alarms where you can find them.
- For 2β4 weeks: a fuel plan (stored away from the house), a food plan (fridge first, freezer later), and a check-in plan with family or neighbors, especially for medical equipment.
Frequently Asked Questions
Do I need to power my whole house?
No. Most people only need a few things: phones, lights, a CPAP, the fridge. That's why our example kits start with Tier 1 at about 200Wh a day.
What is the lowest-cost kit that works?
For phones, lights and a radio or router, the Jackery Solar Generator 300 v2 kit ($419) with about 50β75 minutes of generator a day in weak sun. Without a generator, the Jackery Explorer 1000 v2 kit ($686) rates β Strong for 1, 2 and 4 weeks.
Can a kit run my CPAP?
Yes, at about 40W for 8 hours a night with no heated humidifier or hose. The EcoFlow DELTA 3 Max kit rates β Strong for a week of Tier 2 and the BLUETTI AC200PL kit for 1 to 4 weeks; the BLUETTI AC180P + 350W kit rates π‘ Good for 1 week. Check your machine's label and follow your supplier's or doctor's advice.
Fridge and CPAP together?
That is about 1,910Wh a day, close to Tier 4. Use a Tier 4 kit or ask us to size one.
Can solar alone run a refrigerator?
With a big enough kit, in our model. The Tier 3 examples last about 2 to 3 days in weak sun, then need a daily generator top-up. For no generator, see the TITAN 5000 Classic + 10 panels in the picker, or the Tier 4 kits.
Can I charge it while it powers my things?
Most power stations can (pass-through charging), with limits. See pass-through charging.
What if a product in a kit sells out?
Its page will show sold out. Call, text or email us and we'll suggest the current best option.
Do you ship to Puerto Rico, Hawaii, Alaska and U.S. territories?
Many items ship there. Ask us about your location. Island and territory customers can add our Shipping Assist Program.
Need help choosing?
Tell us what you want to run and for how long, and we'll recommend the right size for your budget. No pressure.
- Email: care@powerfitshop.com
- Call or text: 352-561-8443
Deep Dive: Tables, Methods and Definitions
For readers who want the details behind the numbers. Tap a section to open it.
Typical Watts for Common Devices
A starting point. Check the label on your own device. If it lists only volts and amps, volts Γ amps gives the most it can draw, which is usually more than it really uses.
| Device | Typical watts | Typical use | About Wh a day | Notes |
|---|---|---|---|---|
| Full-size refrigerator | Cycles on and off. A DOE Energy Saver typical-wattage list (republished by TCNJ) gives 725W for one 16 cu ft frost-free model; that is a label-style rating, not what it draws all day | 24 hours, compressor runs part of the time | About 1,200Wh (our planning figure; many use 1,000β1,400Wh) | Best: measure it or use the EnergyGuide label |
| Chest freezer | Check the label | Cycles on and off | EnergyGuide kWh Γ· 365 Γ 1,000 | Example: a 250 kWh/year label β 685Wh a day |
| CPAP, no heated humidifier or hose | About 30β60W (our How to Choose guide); we plan with 40W | 8 hours | About 320Wh at 40W | Check your machineβs label or manual |
| CPAP with heated humidifier and hose | Varies a lot | 8 hours | Can be double or more | Ask your equipment supplier |
| Fan | Window 55β250W, ceiling 65β175W [DOE]; small fan about 30W (our figure) | 8 hours | About 240Wh for a 30W fan | A small DC or USB fan uses less |
| Wi-Fi router and modem | About 10β25W together (our How to Choose guide); we plan with 15W | 24 hours | About 360Wh at 15W | Check both power adapters |
| Phone | Its battery holds about 15β20Wh | 1 charge | About 19β25Wh after the Γ· 0.8 loss | Charge from a USB port |
| Laptop | About 50W [DOE]; 45β100W (our How to Choose guide) | 4 hours | About 200Wh at 50W | Check the charger label |
| TV | About 120W flat screen [DOE]; LED TVs 60β150W (our How to Choose guide) | 4 hours | About 240β600Wh | Newer LED TVs often use less |
| LED light bulb | About 8β12W (our How to Choose guide) | 5 hours | About 50Wh at 10W | Far less than old bulbs |
| Microwave | Cooking power 750β1,100W [DOE], but it draws more from the outlet. Sharpβs SMC1111AB, for example, cooks at 1,000W and lists 1,500W input | 10 minutes | About 250Wh at 1,500W input | Size by the input watts or amps on the label, not the cooking watts |
| Clock radio | About 10W [DOE] | 24 hours | About 240Wh | A battery radio uses none |
| Window air conditioner | Check the label | Hours a day | High | Big startup surge. Call us first |
[DOE] = typical wattages from the U.S. Department of Energy's Energy Saver appliance list, read via the copy republished by The College of New Jersey (TCNJ). Real use depends on the model and settings.
Measure Your Fridge in 24 Hours
- Get a plug-in watt meter (also called a kWh meter). Plug it into the wall and the fridge into it.
- Leave it for at least 24 hours of normal use; 2β3 days is better. Then read the kWh.
- Do the math: kWh Γ· days Γ 1,000 = Wh a day. Example: 2.4 kWh over 2 days = 1,200Wh a day.
- No meter? Use the yellow EnergyGuide label: yearly kWh Γ· 365 Γ 1,000. A 450 kWh/year label is about 1,230Wh a day. Labels are lab numbers, so a hot room, an old door seal or lots of door opening can raise real use.
- Starting watts: some meters show a max-watts reading, but a compressor start can be too quick to catch. Use your fridge maker's info or ask us.
Keep the fridge at 40Β°F or below and the freezer at 0Β°F (U.S. food-safety guidance), keep the door closed, and fill empty space with water jugs.
Make Your Own List
| My device | Watts (from the label) | Hours a day | Watts Γ hours = Wh a day |
|---|---|---|---|
| Example: LED lamp | 10W | 5 | 50Wh |
| Power station idle draw (if AC stays on) | From the manual | Hours the AC is on | |
| My total | ____ Wh a day |
Then divide your total by 0.8 for the energy lost inside the power station (about 20%). So 200Wh a day becomes 250Wh a day. That is what the battery and panels have to cover each day.
Sun Hours Where You Live (PVWatts)
Modeled equivalent full-sun hours a day on a fixed panel facing true south, tilted at the local latitude, in a typical weather year:
| Location | Year average | Lowest month | Best month |
|---|---|---|---|
| The Villages, FL | 5.5 | 4.7 (Dec) | 6.4 (May) |
| Miami, FL | 5.6 | 4.7 (Dec) | 6.4 (Mar) |
| San Juan, PR | 5.9 | 5.3 (Dec) | 6.4 (Mar) |
| Honolulu, HI | 5.8 | 4.9 (Dec) | 6.5 (Sep) |
| Anchorage, AK | 3.0 | 0.5 (Dec) | 4.8 (May) |
| Phoenix, AZ | 6.6 | 5.4 (Dec) | 7.5 (Apr) |
| Houston, TX | 5.2 | 3.8 (Dec) | 5.8 (Jul) |
| Atlanta, GA | 5.1 | 3.9 (Dec) | 5.8 (May) |
| Denver, CO | 5.7 | 4.6 (Dec) | 6.3 (Sep) |
| New York, NY | 4.5 | 2.9 (Dec) | 5.4 (Jul) |
| Chicago, IL | 4.5 | 2.7 (Dec) | 5.9 (Jul) |
| Seattle, WA | 3.8 | 1.6 (Dec) | 5.9 (Aug) |
Source: PVWatts v8 from the U.S. Department of Energy's National Laboratory of the Rockies (formerly NREL), NSRDB typical-year weather. Settings: fixed open-rack array, azimuth 180Β° (true south), tilt = latitude, standard module, 1kW system, 14% system losses. The figure is monthly sun on the panel surface (kWh per mΒ² a day), which equals full-sun hours; system size and losses don't change it. Look up your own address free at pvwatts.nlr.gov. These are averages: a hurricane or winter storm can bring several days far below them.
Cloudy Days: How Long Each Kit Lasts
Days of power before the battery runs out, starting full, for each kit's own tier. Rounded down to avoid false precision. "Keeps going" means the panels cover the whole day.
| Kit (starting full) | No sun | Stormy (1 h) | Weak sun (3 h) | Good sun (5 h) |
|---|---|---|---|---|
| Tier 1: Jackery Explorer 300 v2 + 40W panel | about 1 day | about 1Β½ days | about 2 days | about 3 days |
| Tier 1: Jackery Explorer 1000 v2 + 100W panel | 4+ days | 6+ days | 40+ days | Keeps going |
| Tier 2: EcoFlow DELTA 3 Classic + 160W panel | about 1 day | about 1 day | about 1Β½ days | about 3 days |
| Tier 2: EcoFlow DELTA 3 Max + 2 panels | about 2 days | about 3 days | 8+ days | Keeps going |
| Tier 3: EcoFlow DELTA 3 Max + 2 panels | about 1 day | about 1Β½ days | about 2 days | 4+ days |
| Tier 3: BLUETTI AC200PL + 2 panels | about 1Β½ days | about 1Β½ days | about 3 days | 12+ days |
| Tier 4: EcoFlow TITAN 5000 Classic + 10 panels | about 2 days | about 2Β½ days | 12+ days | Keeps going |
| Tier 4: Anker SOLIX 2 Γ F3800 Plus + 2 panels | about 3 days | 3+ days | 11+ days | Keeps going |
| Tier 4: Jackery HomePower 1000 Plus v2 + 5 packs + 4 panels | 4+ days | 4+ days | 6+ days | 9+ days |
| Tier 4: BLUETTI Apex 300 + 6 Γ B500K + 2 panels | 12+ days | 15+ days | 30+ days | 60+ days |
Big Panel Arrays: Space, Weight and Setup
The Tier 4 kits use many panels. Before you buy, make sure you have the space and help to set them up after a storm.
| Kit | Panels | Panel area (no gaps) | Panel weight | Setup |
|---|---|---|---|---|
| EcoFlow TITAN 5000 Classic + 10 panels | 10 Γ EcoFlow 100W rigid (98 Γ 58.6 cm, 13.7 lb) | about 62 sq ft | about 137 lb | Rigid panels on mounting feet; 2 strings of 5 joined with the included Victron MC4-Y pair (not an EcoFlow part; see the warranty note below) |
| EcoFlow TITAN 5000 Classic + 14 panels | 14 Γ EcoFlow 100W rigid (98 Γ 58.6 cm, 13.7 lb) | about 87 sq ft | about 192 lb | Rigid panels on mounting feet; 2 strings of 7 joined with the included Victron MC4-Y pair (not an EcoFlow part; see the warranty note below) |
| Anker SOLIX 2 Γ F3800 Plus + 2 panels | 2 Γ Anker SOLIX 440W rigid (172 Γ 113 cm, 46.3 lb) | about 42 sq ft | about 93 lb | Large rigid panels, wired within each F3800 Plus input limit (we send the wiring plan) |
| Anker SOLIX 2 Γ F3800 Plus + 4 panels | 4 Γ Anker SOLIX 440W rigid (172 Γ 113 cm, 46.3 lb) | about 84 sq ft | about 185 lb | Large rigid panels, wired within each F3800 Plus input limit (we send the wiring plan) |
| Jackery HomePower 1000 Plus v2 + 5 packs + 4 panels | 4 Γ Jackery SolarSaga 100W Air, unfolded (167 Γ 42 cm, 7.05 lb) | about 30 sq ft | about 28 lb | Light folding panels; paired with the two included Jackery connectors |
| BLUETTI Apex 300 + 6 Γ B500K + 2 panels | 2 Γ BLUETTI PV350 folding, unfolded (240 Γ 91 cm, 30.6 lb) | about 47 sq ft | about 61 lb | Folding panels, one per solar input (same 2 panels in all three BLUETTI kits) |
- Area is the panels alone. Leave gaps between rows, and pick a spot with no shade from about 9 a.m. to 3 p.m.
- Rigid panels need mounting feet or a rack and two people to place. Folding panels are lighter but still need staking down in wind.
- Take panels in or lay them flat and secure them before high winds, then set them back out once it's safe.
- Each kit's wiring stays within the maker's published voltage and current limits. Adding panels? Ask us first.
Pass-Through Charging: Charge and Power at Once
Pass-through means the power station charges and powers your devices at the same time. Most units here support it, but check your manual for the limits. For example, Jackery lists 1,500W max AC output while the Explorer 1500 v2 is charging and discharging at once, and EcoFlow's TITAN 5000 Classic runs its outlets in a "bypass mode" when charging from AC.
- When charging from a generator, it supplies the charging and what's plugged in. Add them before you choose the generator size.
- A fridge starting while charging adds a surge to the generator too.
- Check both manuals for generator grounding and neutral notes. Some UPS and auto-switch features behave differently on generator power.
- Solar charging and AC charging can usually run together; how the unit splits them varies by model.
Solar Panel Tips, Voltage Limits and Storm Prep
- Face the sun. Point panels toward true south and tilt them toward the sun. Folding panels can be turned 2 or 3 times a day to follow it.
- Avoid shade. Even a little shade from a branch or railing can cut output a lot.
- Keep them clean of dust, pollen, leaves and snow.
- Check the water rating (IP rating). Jackery rates the SolarSaga 40W Air IP68. Keep connectors off wet ground, and keep the power station itself indoors and dry.
- Keep the battery warm enough to charge. Many units will not charge below freezing. Jackery lists 32β113Β°F for charging the Explorer 1000 v2, and EcoFlow lists the same for the DELTA 3 Max.
- Don't cover a power station while it is charging or running.
- Run the cable through a window gap, sealed with a towel or draft stopper.
Battery Basics: LiFePO4, Cold and Heat
LiFePO4 (lithium iron phosphate) is used in every unit in this guide's tables. It is more thermally stable than older lithium types.
- Long life: makers rate these units at about 3,000β6,000 cycles, but they count differently. Jackery rates the Explorer 1000 v2 at 4,000 cycles to 70%+ capacity, Anker rates the C1000 Gen 2 at 4,000 cycles to 80%, and BLUETTI rates the AC180P at 3,500+ cycles to 80%.
- Batteries also age with time, heat and storage, and a unit may stop before 0% to protect itself.
- Storage: follow the maker's storage charge level and top it up every few months.
Upgrade Path: Start Small, Grow Later
- Start with Tier 1 or 2. Cover phones, lights and medical needs first.
- Add a panel if the power station has room on its solar input, within the maker's limits.
- Add an expansion battery where supported. The Jackery HomePower 1000 Plus v2 ($926 kit) takes up to five Battery Pack 2000 Plus v2 packs (Jackery: 1β11kWh). One pack is our Tier 3 example ($2,097); five packs is our Tier 4 Jackery example.
- Add a generator for long cloudy stretches.
- Connecting to your house? That needs a transfer switch, interlock or smart home panel installed by a licensed electrician. Never use a "double-male" cord: it can send power back into the lines and is dangerous.
What These Kits Are Not Planned For
| Tier | Planned for | Not planned for |
|---|---|---|
| 1 | Phones, two LED lamps, a radio or router | A fridge, a CPAP all night (thatβs Tier 2), a microwave, anything that heats |
| 2 | Tier 1 plus a CPAP (no heated humidifier) and a small fan | A fridge or freezer, heating or AC, cooking |
| 3 | A full-size fridge, phones, lamps | A CPAP too (use Tier 4), a second fridge or freezer, a well pump, window AC, space heaters, electric cooking |
| 4 | A fridge, Wi-Fi all day, five lights, phones, a laptop | Central AC, electric water heater, range or dryer, a 240V well pump, house circuits without an electrician |
How We Calculated This
- Daily use: watts Γ hours for each device, added up.
- One loss rule: daily use Γ· 0.8 = what the battery has to supply each day (about 20% lost inside the power station). We use the battery's full rated Wh with this one rule.
- Solar: panel watts Γ 0.75 Γ peak sun hours (3 for weak sun, 5 for good sun).
- Days: battery Wh Γ· (daily use Γ· 0.8 β solar Wh). If solar covers it, the kit keeps going. Results are rounded down (for example, 42.8 days is shown as "40+ days").
- No-sun reserve: battery Wh Γ· (daily use Γ· 0.8).
- Weather rating: Strong = at least 25% to spare in weak sun, 2+ days of no-sun reserve, and (Tier 3β4) still lasting with 15W extra idle draw; Good = at least 10% to spare; otherwise Needs backup.
- Generator minutes: the daily shortfall Γ· the unit's published AC charging rate, rounded up to 5 minutes; the top of the range adds 50%.
- Sun hours: PVWatts v8 settings in the sun-hours table above.
Not included: very hot or cold weather, battery aging, a low-charge cutoff, devices that differ from ours, and real-world tests. Starting full is assumed.
Common Mistakes to Avoid
- Buying for the whole house when you only need a few essentials.
- Checking only Wh. Check output and surge watts too.
- Using a microwave's cooking watts instead of its input watts.
- Guessing the CPAP number. Heated humidifiers and hoses use a lot more.
- Expecting full panel watts or average sun during a storm.
- Mixing panels the power station wasn't made for.
- Leaving AC on all day for a phone charger. Use USB.
- Running a generator indoors, in a garage or on a balcony. Outdoors only, 20 feet away.
Plain-English Glossary
- Watt (W)
- How much power something uses right now.
- Watt-hour (Wh)
- Energy over time. 100W for 2 hours = 200Wh. Battery size is in Wh.
- Label watts (nameplate)
- The rating on a device's sticker. Often the most it can draw, not its normal use.
- Surge watts
- The short burst a motor needs to start.
- Power Lifting
- BLUETTI's mode for running heating devices above rated watts at reduced power. Not motor surge.
- Peak sun hours
- Hours of full-strength sun in a day. A cloudy day may have 1 to 3.
- No-sun reserve
- How many days a full battery lasts with no solar at all.
- Open-circuit voltage (Voc)
- A panel's highest voltage. It must stay under the power station's limit.
- Inverter
- The part that turns battery power into normal 120V outlet power.
- Idle draw
- Power a station uses just keeping its outlets on.
- Pass-through charging
- Charging and powering devices at the same time.
- UPS switchover
- When the grid fails, the power station takes over on its own, in milliseconds.
- Cycle
- One full use of the battery, from full to empty and back.
- LiFePO4
- Lithium iron phosphate, a long-life battery type.
- Transfer switch / interlock
- Electrician-installed equipment that safely connects backup power to chosen house circuits.
The Fine Print
*Everything on this page is a planning estimate from manufacturer specs and our math, not a guarantee or a hands-on test. Real results depend on your devices, the weather, temperature and how you use the kit. If you depend on this equipment for something critical, plan for a margin beyond these numbers.
- Battery, output, solar, charging and weight specs come from each manufacturer's official pages and manuals, or our product listings. All example panel setups are within the maker's published input limits.
- The Anker SOLIX C1000 Gen 2 is listed without a panel because the Anker panels that fit it are not in stock right now.
- The Jackery HomePower 1000 Plus v2 + battery pack kit has no published AC charge time with a pack, so ask us about generator time.
- BLUETTI writes the AC200PL's name as "AC200P L". BLUETTI's US page lists the AC180P's 2,700W as both surge and Power Lifting Mode, which is for heating devices, so we don't use it as a motor-starting figure.
- Store prices checked Nov 21, 2026. Prices and stock change.
- Revision: Nov 21, 2026. Weather-resilience ratings with a 2-day no-sun reserve replace "sun alone"; idle-draw stress test for Tiers 3β4; rounded runtimes; weights, break-even sun hours, big-array footprint, pass-through and medical notes; detailed tables moved to the Deep Dive.